Black Millwork

BBA Certification    


400 Series Frenchwood® Hinged Patio Doors
BBA Certificate No. 97/3398

BS 6375-1:1989
Test Pressure
Class (Pa)
MOAT
No.1
Grading
Strength and stability
All Doors
2000 V3
Watertightness
All Doors
300 E3
Air permeability
All Doors
600 A3
Thermal transmittance (U-Factor) for a door 2036mm high by 916mm wide is 1.58±0.16 Wm-2 K-1


400 Series Frenchwood® Outswing Patio Doors

BS 6375-1:1989
Test Pressure
Class (Pa)
MOAT
No.1
Grading
Strength and stability
All Doors
2000 V3
Watertightness
Single-leaf Doors
Two-leaf Doors

150
300

E2
E3
Air permeability
All Doors
600 A3
Thermal transmittance (U-Factor) for a door 2036mm high by 916mm wide is 1.58±0.16 Wm-2 K-1


400 Series Frenchwood® Gliding Patio Doors

BS 6375-1:1989
Test Pressure
Class (Pa)
MOAT
No.1
Grading
Strength and stability
FWG 5068
(1505mm wide x 2019mm high)

FWG 8068
(2419mm wide x 2019mm high)

FWG 8080
(2419mm wide x 2426mm high)


1500


1000


700


V2


V2


V1
Watertightness
All Doors
200 E2
Air permeability
All Doors
600 A3
Thermal transmittance (U-Factor) for a door 2015mm high by 1810mm wide is 1.71±0.17 Wm-2 K-1


Andersen Builders Select Doors

BS 6375-1:1989
Test Pressure
Class (Pa)
MOAT
No.1
Grading
Strength and stability 800 V1
Watertightness 200 E2
Air permeability 600 A2
Thermal transmittance (U-Factor) for a door 2092mm high by 1828mm wide is 2.44±0.24 Wm-2 K-1

Note: Values are a summary of results, see actual BBA certificates for full information.